1374567D01, KCECPU MiniConsole/AMC parameter list, AMC,  SW release version 14.4.0.33
ID Parameter Name Min  Max  Description Category Subcategory
257 Max Number Of Floors 1 250 Max Number of floors
STRUCTURE BUILDING
258 Door Sides At Floor 0 15 Shaft layout
0 = Dummy floor
1 = A side door exist
2 = B side door exist
3 = A & B side doors exist
4 = C side doors exist
5 = A & C side doors exist
6 = B & C side doors exist
7 = A & B & C side doors exist
Note! Values copied from setup data after setup drive.
STRUCTURE BUILDING
259 Floor Markings 0 4294967295 Floor markings for floors 1 ... 250
Default markings 1,2,3,...
STRUCTURE BUILDING
260 Lowest Floor 1 249 Lowest Floor
STRUCTURE BUILDING
261 Highest Floor  2 250 Highest Floor
STRUCTURE BUILDING
262 Main Floor 1 250 Main Floor
STRUCTURE BUILDING
269 Floor to Floor Distance 0 100000 Floor to floor distance in millimeters
STRUCTURE BUILDING
280 Roll Call Direction 0 2 Roll Call (RC) direction (type)
0 = Roll call for car and machine room networks only
1 = Roll call for shaft from up to down
2 = Roll call for shaft from down to up
Note! RC required when parameter value changed.
STRUCTURE BUILDING
282 Roll Call Start Floor 0 250 Roll Call (RC) start floor
0 = according to shaft layout (standard way)
1 ... 250 = Specific Roll call start floor
STRUCTURE BUILDING
300 Lift ID 0 30 Elevator ID in group
STRUCTURE BUILDING
301 Group ID 0 500 Elevator Group ID
STRUCTURE BUILDING
302 Group Type 0 1 Group Type
0 = Single elevator
1 = KCEGC group elevator
STRUCTURE BUILDING
303 Group Connection Timeout 0 300 Timeout in seconds for elevator to connect to KCEGC group.
0 = Single elevator operation not allowed
1 ... max value = timeout in seconds
STRUCTURE BUILDING
304 Connectivity Type 0 1 E-Link and Connectivity
0 = disabled
1 = enabled
STRUCTURE BUILDING
309 APM Supervision 0 1 Alarm Phone Supervision
0 = disabled
1 = enabled
STRUCTURE BUILDING
310 Nominal Load of Elevator Car 0 20000 Maximum car load in kilograms
STRUCTURE BUILDING
398 I/O Configuration Type 0 1 Defines I/O configuration file in use
0 = Default SW I/O configuration file always in use
1 = Customized I/O configuration file in use if any
STRUCTURE BUILDING
399 FCB IO mapping  0 8 Defines I/O map used on FCB board for OSI/HSL/IUL and Up Call outputs
0 = I/O configuration file in use
1 = FC control, up & dn buttons separated, OSI in use.
2 = DC/PB control, dn button used for calls. OSI & HSL in use.
3 = DC/PB control, dn button used for calls. IUL & HSL in use.
4 = DC/PB control, dn button used for calls. IUL & OSI in use.
5 = DC/PB control, dn button used for calls. HSL & OSI in use.
6 = Up & dn buttons connected together. OSI in use.
7 = Up & dn buttons connected together. HSL in use.
8 = Up & dn buttons connected together. IUL in use.
STRUCTURE BUILDING
403 IO Pairing for Car Call Buttons 0 1 IO pairing for car call buttons.
0 = disabled
1 = enabled
CALLS NOTSET
404 IO Pairing for Landing Call Buttons 0 1 IO pairing for landing call buttons.
0 = disabled
1 = enabled
CALLS NOTSET
405 Basement Floor Extension 0 1 Basement Floor Extension (FEB)
0 = Disabled
1 = Enabled
CALLS NOTSET
406 Top Floor Extension 0 1 Top Floor Extension (FET)
0 = Disabled
1 = Enabled
CALLS NOTSET
407 Stuck Button Service Type 0 3 Stuck Push Button Service Type (SPB BT)
0 – No service
1 – Serve stuck landing buttons
2 – Serve stuck car call buttons
3 – Serve both car and landing stuck buttons
CALLS NOTSET
408 Stuck Button Service Interval 1 30 Stuck call buttons service interval in minutes.
CALLS TIMES
409 Floor Extension Car 0 1 Floor Extension Car (SLC) call button existence.
0 = Disabled
1 = Enabled
CALLS NOTSET
515 Door Type 0 6 0 = no door
1 = automatic door, parallel interface to door control
2 = automatic door, serial interface to door control
3 = swing door at landing with manual car gate in car
4 = swing door at landing with safety ray in car
5 = swing door at landing + automatic door in car, parallel interface to door control
6 = swing door at landing + automatic door in car, serial interface to door control
DOORS NOTSET
516 Door Open Time 10 600 Basic door open time in 0.1s steps
DOORS TTIMES
517 Door Open Time Main Add 0 300 Additional door time at main floor in 0,1 s steps
DOORS TTIMES
518 Door Open Time Ldg Add 0 300 Additional door time to landing call in 0,1 s steps
DOORS TTIMES
519 Door Reopen Time 1 150 Door reopen time in 0,1 s steps
DOORS TTIMES
520 Door Reopen Allowed By Photocell 0 1 Photocell operation
0 = photocell input disabled
1 = photocell input enabled
DOORS NOTSET
521 Door Reopen Allowed by DOB  0 1 Door reopen allowed by door open button
0 = door reopening disabled by DOB when door closing
1 = door reopening enabled by DOB when door closing
DOORS NOTSET
522 Door Quick Close by New Car Call 0 1 Door quick close by new car call allowed (QCC)
0 = door quick close disabled
1 = door quick close enabled
DOORS NOTSET
523 Door Quickclose By SRC 0 2 Door time shortening by photocell
0 = door time shortening disabled
1 = door time shortening enabled while door fully open
2 = door time shortening enabled while door opening or door fully open
DOORS NOTSET
524 Door Ensured Time For SRC 1 100 Ensured door open time after photocell cut in 0,1 s steps
DOORS TTIMES
525 Door Ensured Time For QCC 1 100 Ensured door open time after new car call in 0,1 s steps
DOORS TTIMES
526 Door Open Limit Supervision Time 10 300 Door open limit supervision time in 0,1 s steps
DOORS TTIMES
527 Door Close Limit Supervision Time 10 300 Door close limit supervision time in 0,1 s steps
DOORS TTIMES
528 Door Opening Time 10 300 Door opening time in 0,1 s steps when door open limit not in use
DOORS TTIMES
529 Door Open Limit In Use 0 1 Door open limit in use
0 = not in use
1 = in use
DOORS NOTSET
530 Door Close Limit In Use 0 1 Door close limit in use
0 = not in use
1 = in use
DOORS NOTSET
531 Door Nudging Type 0 4 Nudging type (NUD)
0 = not in use
1 = in use, DOB inoperative
2 = in use, DOB remains operative
3 = in use, DOB inoperative, load detection
4 = in use, DOB remains operative, load detection
DOORS NOTSET
532 Door Nudging Time (NUD) 1 1200 Nudging time in 0,1 s steps
DOORS TTIMES
533 Door Nudging Short Time 1 1200 Shortened Nudging time in 0,1 s steps
DOORS TTIMES
534 Door Open Too Long Time 1 3000 Timeout for door open too long fault in 0,1 s steps
DOORS TTIMES
535 Door Closing Try Limit 1 10 Maximum number of door closing trials
DOORS NOTSET
536 Door Closed Torque 0 3 Door torque control (close command)
0 = torque released when door closed, default
1 = torque not released when door closed/locked
2 = torque released even door locked
3 = torque released at door close limit
DOORS NOTSET
541 Door Contact (Car) Filter Time 0 50 Filtering time for car door contact bouncing in 0,1 s steps
DOORS TTIMES
542 Door Open Delay 0 50 Door opening delay at stopping in 0,1 s steps
DOORS TTIMES
544 Door Reopen By Landing Call 0 11 Door reopening by landing call (REO)
0 = not in use
1-10 = number of reopenings allowed (REO O, REO S)
11 = reopen by landing call, Hong Kong  (REO HK)
DOORS NOTSET
545 Door Torque Reset Time 1 200 Door torque time when elevator vacant
Defines time to keep close command (torque) ON still after car door contact closed in 0,1 s steps
DOORS TTIMES
546 Door Retiring Ramp Full Voltage Time 0 200 Retiring ramp magnet control full voltage time 
Defines time to keep full voltage in RR circuitry when RR energized in 0,1 s steps
0 = Full voltage in use all the time
1 ... 200 = Full voltage time (0,1s ... 20s)
DOORS TTIMES
547 Door Close Limit Polarity 0 1 Polarity of door close limit contact while door closed (CDL C)
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DOORS NOTSET
548 Door Open Limit Polarity 0 1 Polarity of door open limit contact while door open (CDL O)
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DOORS NOTSET
549 Door Opened Torque 0 2 Door torque control when door is open
0 = torque released when door fully opened
1 = torque not released when door fully opened
2 = torque is released 3 seconds after door fully opened
DOORS NOTSET
550 Door Open Type for DOE 0 3 Type of Door opening with extended door time button/switch (DOE)
0 = DOE not in use
1 = DOE B (button) in use
2 = DOE S (switch)
3 = DOE T (toggle switch)
DOORS NOTSET
551 Door Open Time for DOE B 10 6000 Door open time for extended door open button DOE B/T in 0,1 s steps
DOORS TTIMES
552 Door Contact Bouncing Filter Time (swing door) 0 50 Filtering time for swing door contact (H4) bouncing in 0,1 s steps
DOORS TTIMES
553 Door Opening Delay with Car Door Lock (LOA) 0 40 Delay for car door opening if LOA or retiring ramp is in use by 0,1 s steps
DOORS TTIMES
554 Door DOE buzzer 0 1 DOE buzzer control, (DOE *I)
0 = buzzer disabled
1 = buzzer enabled
DOORS NOTSET
555 Door Nudging output in use 0 1 Nudging output in use
0 = separate Nudging output not in use (close/open output combination used instead)
1 = separate Nudging output in use
DOORS NOTSET
556 Door Full Speed Time Closing 0 100 Door closing time at full speed with timer controlled (inverter) door in 0,1 s steps
0 = Full speed used permanently
1 ... 100 = time for full speed (0,1s ... 10s)
DOORS TTIMES
557 Door Full Speed Time Opening 0 100 Door opening time at full speed with timer controlled (inverter) door in 0,1 s steps
0 = Full speed used permanently
1 ... 100 = time for full speed (0,1s ... 10s)
DOORS TTIMES
559 Door Retiring Ramp Control at Stop 0 1 Defines retiring ramp control for manual landing door at stopping phase when automatic car door is in use.
0 = retiring ramp de-energizes before car door opening
1 = retiring ramp de-energizes when car door fully opened
DOORS NOTSET
560 Door Retiring Ramp Control at Start 0 1 Defines retiring ramp control for manual landing door at starting phase when automatic car door is in use.
0 = retiring ramp energizes when landing door and car door are closed
1 = retiring ramp energizes when landing door is closed
DOORS NOTSET
562 Door Retiring Ramp Operation with Safety Ray 0 1 Defines retiring ramp operation at door zone after safety ray cut.
0 = Retiring ramp de-energizes when lift stopped at door zone
1 = Retiring ramp de-energizes only when lift stopped at accurate floor level (EMO-AT)
DOORS NOTSET
564 Door Close Button Polarity 0 1 Door Close Button (DCB) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DOORS NOTSET
565 Door Open Button Polarity 0 1 Door Open Button (DOB) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DOORS NOTSET
566 Door Photocell Polarity 0 1 Photocell (SRC) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DOORS NOTSET
567 Door Pressure Limiter Polarity 0 1 Door Pressure Limiter polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DOORS NOTSET
568 Door Direction Change Delay 0 100 Interval time between door open and close commandi in 10 ms steps.
DOORS TTIMES
569 Car Gate Vacant State 0 1 Automatic car door position when elevator is vacant
0 = door parked open
1 = door closed
DOORS NOTSET
570 Door Photocell Supervision 0 1 Phtocell Uninterrupted Monitoring
0 = disabled
1 = enabled
DOORS NOTSET
571 Door Photocell Supervisions Stops 2 10 Number of stops for photocell uninterrupted monitoring
DOORS NOTSET
572 Door Locking of Landing Doors (LLD) 0 1 Locking of landing doors (LLD)
0 = disabled
1 = enabled
DOORS NOTSET
573 Door Ensured Opening Time 1 40 Ensured door opening time in 0,1 s steps
DOORS TTIMES
574 Door Landing Door Lock Monitoring Time 5 50 Defines monitoring time for landing door lock contact in 0,1 s steps
DOORS TTIMES
575 Door Contact Monitoring at Powerup 0 1 0 = disabled
1 = enabled
DOORS NOTSET
576 Door Car Door Contact Monitoring 0 1 0 = disabled
1 = enabled
DOORS NOTSET
577 Door Landing Door Lock Contact Monitoring 0 1 0 = disabled
1 = enabled
DOORS NOTSET
580 Door Mixed Landing Doors 0 1 0 = disabled
1 = enabled
DOORS NOTSET
581 Door Landing Door Type 0 7 Door Type at Landing
0 = automatic landing doors in use
1 = manual door at landing, A side
2 = manual door at landing, B side
3 = manual door at landing, A & B side
4 = manual door at landing, C side
5 = manual door at landing, A & C side
6 = manual door at landing, B & C side
7 = manual door at landing, A & B & C side
DOORS NOTSET
582 Door Simultaneous Opening Forbidden 0 1 Simultaneous Door Opening Forbidden (TTC CTF)
0 = disabled
1 = enabled
DOORS NOTSET
583 Door DCB Operation during DCS Door Hold Open Time 0 1 DCB operation during hard door hold open time
0 = disabled
1 = enabled
DOORS NOTSET
584 FCC D Feature 0 1 FCC D, False destination call cancel by cutting safety rays, DCS
0 = disabled
1 = enabled
OPTIONS NOTSET
585 TTC CTF Door Side Selection 0 3 0 = Open A Side first
1 = Open B Side first
2 = Open C Side first
3 = Open Car call side first
OPTIONS NOTSET
586 LLD Supervision Floor and Side 0 7 0 = Disabled
1 = LLD Supervision Enabled in A
2 = LLD Supervision Enabled in B
3 = LLD Supervision Enabled in A & B
4 = LLD Supervision Enabled in C
5 = LLD Supervision Enabled in A & C
6 = LLD Supervision Enabled in B & C
7 = LLD Supervision Enabled in A, B & C
DOORS NOTSET
699 Door Motion Profile 20 200 Door motion profile adjustment in percentage (%).
This affects to normal opening speed, closing speed and acceleration profile of serial interface door.
DOORS NOTSET
701 KRM Server Ports 0 65535 First index: TCP port of primary KMC
Second index: TCP port of backup KMC
Third index: TCP port of Alarm Phone
STRUCTURE BUILDING
702 KRM Heartbeat Interval 0 65535 KRM heartbeat interval in minutes
0 = heartbeat disabled
1-1440 = interval in minutes
65535 = automatic
STRUCTURE BUILDING
703 KMC Primary Host 0 4294967295 IP address or host name of primary KMC
STRUCTURE BUILDING
704 KMC Backup Host 0 4294967295 IP address or host name of backup KMC
STRUCTURE BUILDING
705 Alarm Phone Host 0 4294967295 IP address or host name of Alarm Phone
STRUCTURE BUILDING
721 DCI Host 0 4294967295 Device Certification Interface IP address or host name
STRUCTURE BUILDING
722 DCI Port 1 65535 Device Certification Interface TCP port
Index1: HTTP port
Index2: HTTPS port
STRUCTURE BUILDING
723 MQTT Broker Host 0 4294967295 MQTT broker IP address or host name
STRUCTURE BUILDING
724 MQTT Broker Port 1 65535 MQTT broker TCP port
STRUCTURE BUILDING
725 GCD Service Discovery 0 1 Service discovery method for Group and Connectivity services
0 = Manual configuration
1 = Automatic discovery, VAMP
STRUCTURE BUILDING
726 Inventory Manager Address 0 4294967295 Inventory Manager IP address or host name
STRUCTURE BUILDING
727 Inventory Manager TCP Port 1 65535 Inventory Manager TCP port
Index1: HTTP port
Index2: HTTPS port
STRUCTURE BUILDING
728 SFS Host 0 4294967295 Synchronized File Storage IP address or host name
STRUCTURE BUILDING
729 SFS Port 1 65535 Synchronized File Storage TCP port
STRUCTURE BUILDING
740 Timezone Offset 0 72000 Current timezone offset

Index1: absolute offset in seconds from UTC
Index2: direction, 0=after UTC, 1=before UTC
STRUCTURE BUILDING
741 Time Announcement Updates 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
750 Daily IOTSend Delay 0 72000 Delay for daily data transmission to IoT cloud in seconds after midnight
OPTIONS TIMES
800 KPI Daily Statistics Buffer Size 1 3 KPI daily statistics buffer size

Defines how many days of condition KPI daily statistics data are buffered by the KCECPU.
STRUCTURE BUILDING
802 KPI Sample Size 10 50 Number recent samples recorded for selected KPIs
STRUCTURE BUILDING
804 KPI Selection 0 49 Select KPIs to be stored on non-volatile storage

0 = None
1 = KPI_RESERVED_ID
2 = KPI_DOOR_OPEN_TIME_ID
3 = KPI_DOOR_CLOSE_TIME_ID
4 = KPI_START_DELAY_TIME_ID
5 = KPI_FLIGHT_TIME_ID
6 = KPI_DOOR_PRE_OPEN_TIME_ID
7 = KPI_SHAFT_TEMPERATURE_ID
8 = KPI_CLOSING_DEVICE_ENERGY_ID
9 = KPI_DOOR_FRICTION_ID
10 = KPI_HEATSINK_TEMPERATURE_ID
11 = KPI_CONTROL_BOARD_TEMPERATURE_ID
12 = KPI_MOTOR_TEMPERATURE_ID
STRUCTURE BUILDING
        13 = KPI_DC_VOLTAGE_ID
14 = KPI_RELATIVE_EBC_VALUE_ID
15 = KPI_RELATIVE_POSITION_DRIFT_ID
16 = KPI_RELATIVE_POSITION_DIFF_ID
17 = KPI_KTWQ_ESTIMATE_ID
18 = KPI_LWD_VALUE_ID
19 = KPI_START_ACCURACY_ID
20 = KPI_STOPPING_QUALITY_ID
21 = KPI_MECH_BRAKE_A_CURRENT_ID
22 = KPI_MECH_BRAKE_A_MOVEMENT_ID
23 = KPI_MECH_BRAKE_B_CURRENT_ID
24 = KPI_MECH_BRAKE_B_MOVEMENT_ID
   
        25 = KPI_CONST_SPEED_QUALITY_ID
26 = KPI_RELATIVE_PULSE_ERROR_ID
27 = KPI_AVERAGE_SHAFT_FRICTION_ID
28 = KPI_CURRENT_AT_NOMINAL_SPEED_ID
29 = KPI_COOLING_FAN1_SPEED_ID
30 = KPI_COOLING_FAN2_SPEED_ID
31 = KPI_KDSI2_ERRONEOUS_MESSAGES_ID
32 = KPI_KDSI2_MISSING_MESSAGES_ID
33 = KPI_KDSI2_DISTURBANCES_ID
   
        34 = KPI_TTS1_ERRONEOUS_MESSAGES_ID
35 = KPI_TTS1_MISSING_MESSAGES_ID
36 = KPI_TTS1_DISTURBANCES_ID
37 = KPI_TTS2_ERRONEOUS_MESSAGES_ID
38 = KPI_TTS2_MISSING_MESSAGES_ID
39 = KPI_TTS2_DISTURBANCES_ID
40 = KPI_KCDI_ERRONEOUS_MESSAGES_ID
41 = KPI_KCDI_MISSING_MESSAGES_ID
42 = KPI_KCDI_DISTURBANCES_ID
43 = KPI_LDG_DOOR_CLEARANCE_ID
   
        44 = KPI_CAR_DOOR_CLEARANCE_ID
45 = KPI_LOCK_HOOK_TIME_ID
46 = KPI_CUMMILATIVE_SPEED_REF_ID
47 = KPI_MAX_SPEED_REF_ID
48 = KPI_BELT_MOV_AFTER_COUPLER_RELAXATION_ID
49 = KPI_TIME_AFTER_COUPLER_RELAXATION_ID
   
805 KPI door to door time floor 1 250 Target floor for door-to-door KPI measurements
STRUCTURE BUILDING
806 KPI Latest Sample Selection 0 49 KPI selection for latest samples collection

0 = None
1 = KPI_RESERVED_ID
2 = KPI_DOOR_OPEN_TIME_ID
3 = KPI_DOOR_CLOSE_TIME_ID
4 = KPI_START_DELAY_TIME_ID
5 = KPI_FLIGHT_TIME_ID
6 = KPI_DOOR_PRE_OPEN_TIME_ID
7 = KPI_SHAFT_TEMPERATURE_ID
8 = KPI_CLOSING_DEVICE_ENERGY_ID
9 = KPI_DOOR_FRICTION_ID
10 = KPI_HEATSINK_TEMPERATURE_ID
STRUCTURE BUILDING
        11 = KPI_CONTROL_BOARD_TEMPERATURE_ID
12 = KPI_MOTOR_TEMPERATURE_ID
13 = KPI_DC_VOLTAGE_ID
14 = KPI_RELATIVE_EBC_VALUE_ID
15 = KPI_RELATIVE_POSITION_DRIFT_ID
16 = KPI_RELATIVE_POSITION_DIFF_ID
17 = KPI_KTWQ_ESTIMATE_ID
18 = KPI_LWD_VALUE_ID
19 = KPI_START_ACCURACY_ID
20 = KPI_STOPPING_QUALITY_ID
   
        21 = KPI_MECH_BRAKE_A_CURRENT_ID
22 = KPI_MECH_BRAKE_A_MOVEMENT_ID
23 = KPI_MECH_BRAKE_B_CURRENT_ID
24 = KPI_MECH_BRAKE_B_MOVEMENT_ID
25 = KPI_CONST_SPEED_QUALITY_ID
26 = KPI_RELATIVE_PULSE_ERROR_ID
27 = KPI_AVERAGE_SHAFT_FRICTION_ID
28 = KPI_CURRENT_AT_NOMINAL_SPEED_ID
29 = KPI_COOLING_FAN1_SPEED_ID
   
        30 = KPI_COOLING_FAN2_SPEED_ID
31 = KPI_KDSI2_ERRONEOUS_MESSAGES_ID
32 = KPI_KDSI2_MISSING_MESSAGES_ID
33 = KPI_KDSI2_DISTURBANCES_ID
34 = KPI_TTS1_ERRONEOUS_MESSAGES_ID
35 = KPI_TTS1_MISSING_MESSAGES_ID
36 = KPI_TTS1_DISTURBANCES_ID
37 = KPI_TTS2_ERRONEOUS_MESSAGES_ID
38 = KPI_TTS2_MISSING_MESSAGES_ID
   
        39 = KPI_TTS2_DISTURBANCES_ID
40 = KPI_KCDI_ERRONEOUS_MESSAGES_ID
41 = KPI_KCDI_MISSING_MESSAGES_ID
42 = KPI_KCDI_DISTURBANCES_ID
43 = KPI_LDG_DOOR_CLEARANCE_ID
44 = KPI_CAR_DOOR_CLEARANCE_ID
45 = KPI_LOCK_HOOK_TIME_ID
46 = KPI_CUMMILATIVE_SPEED_REF_ID
47 = KPI_MAX_SPEED_REF_ID
48 = KPI_BELT_MOV_AFTER_COUPLER_RELAXATION_ID
49 = KPI_TIME_AFTER_COUPLER_RELAXATION_ID
   
810 No Service Activation 0 3 Enables/Disables noServicePredict and noServiceReact messages to be sent to KRM/Cloud
0 = noServicePredict and noServiceReact disabled
1 = noServicePredict enabled
2 = noServiceReact enabl
3 = noServicePredict and noServiceReact enabled
OPTIONS NOTSET
853 Lock Override PRL 0 1 Car call locks overridden in PRL modes
0 = disabled
1 = enabled

Index1 (PRL L)
Index2 (PRL H)
Index3 (HEL)
LOCKS NOTSET
854 PRL High Priority Call Type 0 1 Defines High Priority at landing call type
0 = PRL H call
1 = HEL call
OPTIONS NOTSET
855 PRL High Mode Display Type 0 1 Defines PRL H and HEL mode display type in car and at landing
0 = constant
1 = flashing
OPTIONS NOTSET
900 OSS C Pin Code Feature 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
901 PRC Pin Code Feature 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
902 OCL Pin Code Feature 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
903 OCV Pin Code Feature 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
904 Car Call Group Locking PIN code Enabled 0 1 0 = disabled
1 = enabled
LOCKS NOTSET
905 Well Access Protection Activation 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
906 Ride Comfort Test Pin Code 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
910 Pin Code Entry Button 0 240 Button-bus code of PIN code entry button on MUL
0 = MUL key-menu button
1 - 240 = button identifier
OPTIONS NOTSET
997 LOC Override by KCEGC 0 1 Car call lock override from KCEGC allowed
0 = disabled
1 = enabled
LOCKS NOTSET
998 Car Call Group Locking Type 0 1 Car calls group locking type
0 = timer
1 = one call
LOCKS NOTSET
999 Car Call Group Locking Feature 0 1 0 = disabled
1 = enabled
LOCKS NOTSET
1000 Locking Mask for Car Calls (upper deck in double decker) 0 7 Define locking masks for car calls, upper deck
0 = All sides unlocked (000), default
1 = A-side locked (001)
2 = B-side locked (010)
3 = A&B-side locked (011)
4 = C side locked (100)
5 = A & C side locked (101)
6 = B & C side locked (110)
7 = All sides locked (111)

NOTE 1: Requires general lock input to open the locked floors (LOC **G).
NOTE 2: Can be used to lock the floors permanently.
LOCKS NOTSET
1002 Locking Mask for Down Landing Calls 0 7 Define locking masks for down landing calls
0 = All sides unlocked (000), default
1 = A-side locked (001)
2 = B-side locked (010)
3 = A&B-side locked (011)
4 = C side locked (100)
5 = A & C side locked (101)
6 = B & C side locked (110)
7 = All sides locked (111)

NOTE: Not possible to open the lock if activated.
Can be used only to lock the floors permanently.
LOCKS NOTSET
1003 Locking Mask for Up Landing Calls 0 7 Define locking masks for up landing calls
0 = All sides unlocked (000), default
1 = A-side locked (001)
2 = B-side locked (010)
3 = A&B-side locked (011)
4 = C side locked (100)
5 = A & C side locked (101)
6 = B & C side locked (110)
7 = All sides locked (111)

NOTE: Not possible to open the lock if activated.
Can be used only to lock the floors permanently.
LOCKS NOTSET
1004 Enable Car Call Locking (upper deck in double decker) 0 1 0 = disabled
1 = enabled
LOCKS NOTSET
1006 Enable Landing Call Lockings 0 1 0 = disabled
1 = enabled
LOCKS NOTSET
1007 Enable Call Lockings from Option Boards 0 2 Type of calls locked by LOC/LOL inputs typically connected to PIO/OPT boards in machine room network.
0 = car call lockings
1 = landing call lockings
2 = car and landing call lockings

NOTE: Lock type selection needs to be done only when using LOC/LOL inputs.
LOCKS NOTSET
1008 Locking Input Type 0 3 Type of locking inputs
0 = Soft lock for car and landing calls
1 = Hard lock for car and landing calls
2 = Hard lock for car calls and soft lock for landing calls
3 = Hard lock for landing calls and soft lock for car calls

Soft lock does NOT cancel registered call when lock activates.
Hard lock DOES cancel registered call when lock activates.
LOCKS NOTSET
1010 DOB Operation at Car Call Locked Floor 0 2 Door open button (DOB) operation at floor with car call locks
0 = DOB enabled
1 = DOB enabled when door opened once
2 = DOB disabled when door is closed
LOCKS NOTSET
1011 Locked Floor Door Closed Torque Control 0 3 Locked floor door closed torque control
0 = torque releasing allowed
1 = torque releasing not allowed when when car call locked
2 = torque releasing not allowed when when landing call locked
3 = torque releasing not allowed when when car or landing call locked
LOCKS NOTSET
1012 Locking Mask for Landing Calls No Direction 0 7 Define locking masks for landing calls with no direction
0 = All sides unlocked (000), default
1 = A-side locked (001)
2 = B-side locked (010)
3 = A&B-side locked (011)
4 = C side locked (100)
5 = A & C side locked (101)
6 = B & C side locked (110)
7 = All sides locked (111)
LOCKS NOTSET
1013 DOB Operation at Landing Call Locked Floor 0 2 Door open button (DOB) operation at floor with landing call locks
0 = DOB enabled
1 = DOB enabled when door opened once
2 = DOB disabled when door is closed
LOCKS NOTSET
1014 Landing Call Lock Indication Type 0 1 Landing call locking indication type at display
0 = lock icon is shown always when floor is locked
1 = lock icon is shown only when call is pressed at locked floor
LOCKS NOTSET
1015 Locking Override by priority call in car 0 1 Car call locks overridden by priority call in car.
0 = disabled
1 = enabled
LOCKS NOTSET
1016 Locking Override by EPD 0 1 Car call locks overridden in EPD mode
0 = disabled
1 = enabled
LOCKS NOTSET
1017 Landing Lock Operation Group Disconnected 0 3 Landing call lock operation when group elevator operates as single lift.
0 = Follow IO, Landing call lock status follows locking I/O
1 = Last known, Last known landing call lock status copied from group
2 = All open, All landing call locks are set unlocked
3 = All locked, All landing call locks are set locked
LOCKS NOTSET
1018 Locking Override by ATS 0 1 Car call locks overridden in ATS mode
LOCKS NOTSET
1019 General lock in COP 0 1 0 = disabled
1 = enabled

NOTE: Must be enabled before general lock switch can be used (LOC **G). Locked floors are specified by parameter 1000.
LOCKS NOTSET
1020 Advance Door Opening (ADO) 0 1 Advance Door Opening (ADO) feature
0 = disabled
1 = enabled
OPTIONS NOTSET
1021 Advance Door Opening Distance (ADO) 10 125 Defines the point for Advance Door Opening in millimeters.
OPTIONS NOTSET
1070 Gong Volume 0 10 Landing/car gong volume at floors other than main floor
0 = off
1 ... 10 = volume level
OPTIONS GONG
1071 Gong Volume Main 0 10 Landing/car gong volume at main floor
0 = off
1 ... 10 = volume level
OPTIONS GONG
1072 Door Opening by Call during OSS 0 3 Car- / landing call enabling at OSS return floor after OSS return drive (OSS *R)
0 = door opening by car and landing call disabled
1 = door opening by car call enabled
2 = door opening by landing enabled
3 = door opening by car and landing call enabled
OPTIONS NOTSET
1073 Out of Service Return Floor (OSS) 0 252 Out of service (OSS) return floor.
In use when OSS switch connected to OPT or PIO board.

0 = return to nearest floor
1 ... 250  = specified return floor
251 = return to main floor
252 = return to lowest floor
OPTIONS NOTSET
1074 Out of Service Door Open Side (OSS) 0 7 Out of service (OSS) door opening side
0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open
OPTIONS NOTSET
1075 Call Collection Type 1 5 Elevator control system type
1 = Down Collective Control, DC
2 = Full Collective Control, FC
3 = Push Button Control, PB
4 = Memory Push Button Control, MPB
5 = Hybrid Full/Down Collective Control, Hybrid FC/DC
CALLS NOTSET
1076 Opposite Cancel Allowed 0 1 This parameter affects how landing calls registered to both directions are served when no further calls exist.
0 = Landing call that matches the collection direction will be served when the lift stops.
1 = Landing calls in both directions will be served when the lift stops, with no need for collection direction changes.
CALLS NOTSET
1077 Car Call Preference Time 0 100 Car call preference time in 0,1 s steps
CALLS TIMES
1078 Landing Call Cross Coupling Time (LCC) 0 200 Landing call cross coupling time in 0,1 s steps
0 = LCC disabled
1 ... 200 (0,1s ... 20s): LCC enabled
CALLS TIMES
1079 Car Call Backwards (CCB) 0 1 Car call registering against driving direction
0 = car call backwards (CCB) disabled
1 = car call backwards (CCB) enabled
CALLS NOTSET
1080 Car Call Light Cancel Point 0 2 Car call registering light cancel point
0 = when elevator has stopped at destination floor or door starts to open
1 = when elevator starts to decelerate to destination floor
2 = when elevator has stopped to destination floor and doors are fully opened or retiring ramp has released
CALLS NOTSET
1081 Landing Call Light Cancel Point 0 2 Landing call registering light cancel point
0 = when elevator has stopped at destination floor or door starts to open
1 = when elevator starts to decelerate to destination floor
2 = when elevator has stopped to destination floor and doors are fully opened or retiring ramp has released
CALLS NOTSET
1082 Load Weighing Device Type (LWD) 0 2 Load weighing device type
0 = LWD device with analog output (CCG input)
1 = LWD device with potential free contacts (CCG inputs)
2 = LWD device with potential free contacts (OPT inputs)
OPTIONS NOTSET
1083 Full Load Limit 40 100 Full load limit for car load in percentage (%)
OPTIONS NOTSET
1084 Over Load Limit 90 115 Over load limit for car load in percentage (%)
OPTIONS NOTSET
1085 Car Ventilation Type 0 7 Car ventilation (fan) control type
0 = OCV permanently OFF
1 = OCV A (B), automatic
2 = OCV AF (BF) automatic or permanently OFF by switch
3 = OCV K, manual operation, impulse type switch (e.g.button)
4 = OCV I, manual operation, toggle type switch (e.g.button)
5 = OCV M, manual operation
6 = OCV P, car ventilation permanently ON
7 = OCV CV_VI for India
OPTIONS CAR
1086 Car Ventilation Time 0 360000 Delay to turn car ventilation off after last run in 0.1 s steps
OPTIONS CAR
1087 Car Light Type 0 6 Car light control type
0 = OCL permanently OFF
1 = OCL A, auto operation
2 = OCL AF, auto operation or permanently OFF by switch
3 = OCL AT, automatic operation, TEST
4 = OCL I, manual operation, impulse type switch (or button)
5 = OCL M, manual operation
6 = OCL P, permanently ON
OPTIONS CAR
1088 Car Light Time 0 360000 Delay to turn car light off after last run in 0.1 s steps
OPTIONS CAR
1089 Car Light Supervision (CLS) 0 2 Car light supervision type
0 = disabled
1 = enabled, door closed
2 = enabled, door open
OPTIONS CAR
1090 Load Weighing Device error type 0 1 Load weighing device (LWD) error type
0 = Device error disabled, load status follows car load percentage, fault code activated
1 = Device error enabled, load status forced to overload regardless of actual load percentage, fault code activated
OPTIONS NOTSET
1091 OSS Landing Indication Type 0 1 Landing indicator and device operation in OSS mode
0 = landing indicators and devices normal operation
1 = landing indicators and devices turned off
OPTIONS NOTSET
1092 OSS Landing Configuration Type 0 1 OSS Landing Configuration Type
0 = by switch location
1 = by parameters
OPTIONS NOTSET
1095 Landing Device Operation Type 0 1 Operation type for landing devices
0 = Selective landing device operation in use
1 = Non selective landing device operation in use
CALLS NOTSET
1096 Car Operating Panel (COP) Type 0 1 Car operating panel type
0 = Selective door control
1 = Non selective door control
CALLS NOTSET
1097 Door Open Buzzer Type 0 3 Door open buzzer type
0 = no buzzer
1 = DOI IN (door open bell for India)
2 = DOI (door open bell)
3 = CGF MI (car gate buzzer)
OPTIONS NOTSET
1098 Test Generator Type 0 4097 Test generator type
3 = landing calls, run between lowest & highest floor
5 = landing calls, run lowest + 2 and back
9 = landing calls, run random all floors
17 = landing calls, run random all floors, continue after power break
33 = car calls, run between lowest & highest floor
65 = car calls, run lowest + 2 and back
129 = car calls, run random all floors
257 = car calls, run random all floors, continue after power break
513 = run parameterized call sequence, continue after power break
1025 = run programmed call sequence
1026 = run programmed call sequence once
2049 = run parameterized call sequence
4097 =  landing calls, run random all floors, continue after power break, group operation
CALLS TESTGEN
1099 Test Generator Floors 0 4294967295 Test generator floors
bits 1-8: floor number (system internal use)  
bit 9: call ON/OFF in this floor
bits 10-11: call type
                 0 = landing call
                 1 = car call
bits 12-13: call side
                 0 = front side (A)
                 1 = rear side (B)
                 2 = side side (C)
bits 14-15: call direction
                 0 = no direction
                 1 = down direction
                 2 = up direction
bit 16: deck
                 0 = upper deck

CALLS TESTGEN
1100 Car Light Power 0 100 Car light power consumption limits in percentage of learned current
1st index: warning limit
2nd index: error limit
OPTIONS CAR
1101 Car Light Voltage 0 500 Car light supply voltage in 1 volt steps
OPTIONS CAR
1102 Automatic Fault Recovery Time 0 300 Timeout for automatic fault recovering in seconds
OPTIONS TIMES
1103 Battery Supervision Disabled Time 0 22 Car roof battery supervision disabled time in hours (h).
Car roof battery supervision will be disabled for the time given by this parameter.
OPTIONS TIMES
1104 Car Call Cancel at Emergency Stop  0 1 Defines if existing car calls are cancelled at emergency stop.
0 = car calls not cancelled
1 = car calls cancelled
OPTIONS NOTSET
1105 Fault Memory at Emergency Stop  0 1 Defines if emergency stop situation is memorized
0 = not memorized
1 = memorized
OPTIONS NOTSET
1106 Door Movement at Emergency Stop  0 1 Defines if door movement is stopped at emergency stop.
0 = door movement not stopped
1 = door movement stopped
OPTIONS NOTSET
1107 Fault Call Cancel Delay 0 240 Delay in seconds to cancel existing calls in system when fault happens.
OPTIONS TIMES
1108 Test Generator Start Delays 0 20 Additional delay in seconds after door cycle for new start when test generator is active
1st param value: delay when door opening is allowed
2nd param value: delay when door open prohibited by DOP
CALLS TESTGEN
1109 Buzzer Volume 0 10 Buzzer volume at floors other than main floor
0 = off
1 ... 10 = volume level
OPTIONS GONG
1110 Buzzer Volume Main 0 10 Buzzer volume at main floor
0 = off
1 ... 10 = volume level
OPTIONS GONG
1111 Landing Arrow Control 0 1 Landing arrow control with KSS
0 = lanterns (LAL) control in use
1 = arrows (DIA) control in use
OPTIONS NOTSET
1112 Car Light in OSS Mode 0 2 Car light control during OSS mode
0 = car light is turned OFF when door parked open or closed
1 = car light is turned OFF after defined time when door parked open or closed
2 = car light stays ON when door parked open or closed
OPTIONS NOTSET
1113 HSL Type 0 1 Here signal light (HSL)
0 = disabled
1 = enabled
OPTIONS NOTSET
1114 Priority Call in Car Type 1 6 Priority call in car type.
1 = Continuous (PRC K, PRC AU)
2 = Impulse (PRC B)
3 = Russia (PRC CS)
4 = North America (PRC NA)
5 = New Zealand (PRC NZ)
6 = Freight Service (FSC AU+PRC K+PRC AU)
OPTIONS NOTSET
1115 PRC Time 0 300 Timeout in seconds for giving car call during priority call in car (PRC B/T) mode.
OPTIONS NOTSET
1116 GOH IT Type 0 1 Audible indication in car for car door opening
0 = disabled
1 = enabled
OPTIONS NOTSET
1117 Car Call Registered Buzzer (CRB C) 0 1 Car Call registered buzzer (CRB C)
0 = buzzer disabled
1 = buzzer enabled
CALLS NOTSET
1118 Overload indication (OLF) 0 1 Overload indication (OLF)
0 = Constant light
1 = Flashing light
OPTIONS NOTSET
1119 OSS Door Operation 0 1 Door operation in OSS mode
0 = door closes after normal door open time
1 = door remains open
OPTIONS NOTSET
1120 Landing Gong (GOL) 0 1 Landing gong (GOL)
0 = disabled
1 = enabled
OPTIONS NOTSET
1121 Landing Gong Type 0 1 Landing gong (GOL) type
0 = electronic gong
1 = mechanical gong
OPTIONS NOTSET
1122 Landing Gong Trigger Point 1 8 Landing gong (GOL) trigger point
1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time
7 = from group command
8 = immediate landing call allocation
OPTIONS NOTSET
1123 Landing Gong for Car Call 0 1 Landing gong (GOL) operation for car call
0 = disabled
1 = enabled
OPTIONS NOTSET
1124 Number of Landing Gong Sounds, Down 1 3 Landing gong (GOL), number of sounds down
OPTIONS NOTSET
1125 Number of Landing Gong Sounds, Up 1 3 Landing gong (GOL), number of sounds up
OPTIONS NOTSET
1126 Landing Gong Triggering Distance 1 4 Landing gong (GOL) triggering distance in floors
OPTIONS NOTSET
1127 Landing Gong Activation Time in Advance 1 9 Landing gong (GOL) advance activation time in seconds
OPTIONS NOTSET
1128 Landing Gong Pulse Time 1 20 Mechanical landing gong (GOL) pulse time in 0.1 s steps
OPTIONS NOTSET
1129 Time Between Pulses with Landing Gong 1 20 Landing gong (GOL), time between gong pulses in 0.1 s steps
OPTIONS NOTSET
1130 Car Gong (GOC) 0 1 Car gong (GOC)
0 = disabled
1 = enabled
OPTIONS NOTSET
1131 Car Gong Type 0 1 Car gong (GOC) type
0 = electronic gong
1 = mechanical gong
OPTIONS NOTSET
1132 Car Gong Trigger Point 1 8 Car gong (GOC) trigger point
1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time
7 = from group command
8 = immediate landing call allocation
OPTIONS NOTSET
1133 Car gong (GOC) operation for car call 0 1 Car gong (GOC) operation for car call
0 = disabled
1 = enabled
OPTIONS NOTSET
1134 Number of Car Gong Sounds, Down 1 3 Car gong (GOC), number of sounds down
OPTIONS NOTSET
1135 Number Of Car Gong Sounds, Up 1 3 Car gong (GOC), number of sounds up
OPTIONS NOTSET
1136 Car Gong Triggering Distance 1 4 Car gong (GOC) triggering distance in floors
OPTIONS NOTSET
1137 Car Gong Activation Time in Advance 1 9 Car gong (GOC) advance activation time in seconds
OPTIONS NOTSET
1138 Car Gong Pulse Time 1 20 Car gong (GOC) pulse time in 0.1 s steps
OPTIONS NOTSET
1139 Time Between Pulses with Car Gong 1 20 Car gong (GOC), time between gong pulses in 0.1 s steps
OPTIONS NOTSET
1140 Lanterns at Landing (LAL) 0 1 Lanterns at landing (LAL) feature
0 = disabled
1 = enabled
OPTIONS NOTSET
1141 Lantern (LAL) Operation when Lift Vacant 0 1 Lantern (LAL) operation when lift is vacant
0 = both off
1 = both on
OPTIONS NOTSET
1142 LAL Operate as HSL 0 1 Lantern operated as HSL
0 = disabled
1 = enabled
OPTIONS NOTSET
1143 LAL Lantern Operation at Main Floor when Vacant 0 1 Lantern operation at main floor when car is vacant
0 = operation similar to other floors
1 = UP lantern is illuminated
OPTIONS NOTSET
1144 Blinking Lantern at Landing 0 1 Blinking lantern (LAL)
0 = disabled
1 = enabled
OPTIONS NOTSET
1145 LAL Lantern Operation during PRL Mode 0 1 Lantern (LAL) operation during PRL mode
0 = disabled
1 = enabled
OPTIONS NOTSET
1146 LAL Trigger Point 1 8 Lanterm (LAL) trigger point
1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time
7 = from group command
8 = ILA
OPTIONS NOTSET
1147 LAL Triggering Distance 1 4 Lantern (LAL) triggering distance in floors
OPTIONS NOTSET
1148 LAL Triggering Time 1 9 Lantern (LAL) advance activation time in seconds
OPTIONS NOTSET
1149 Lanterns ILA Operation 0 4 Lanterm (LAL) operation with ILA allocation
0 = disabled
1 = constant at allocation - blink at deceleration
2 = blink at allocation - constant at deceleration
3 = blink at allocation - blink at deceleration
4 = constant at allocation - constant at deceleration
OPTIONS NOTSET
1150 Lanterns in Car 0 1 Lanterns in car (LAC) feature
0 = disabled
1 = enabled
OPTIONS NOTSET
1151 Lantern (LAC) Operation when Lift Vacant 0 1 Lantern (LAC) operation when lift is vacant
0 = both off
1 = both on
OPTIONS NOTSET
1152 LAC Operate as HSL 0 1 Lantern operated as HSL
0 = normal LAC operation  
1 = lantern is operating as HSL
OPTIONS NOTSET
1153 LAC Lantern Operation at Main Floor when Vacant 0 1 Lantern operation at main floor when car is vacant
0 = operation similar to other floors
1 = UP lantern is illuminated
OPTIONS NOTSET
1154 Blinking Lantern in Car 0 1 Blinking lantern (LAC)
0 = disabled
1 = enabled
OPTIONS NOTSET
1155 LAC Lantern Operation during PRL Mode 0 1 Lantern (LAC) operation during PRL mode
0 = disabled
1 = enabled
OPTIONS NOTSET
1156 LAC Trigger Point 1 8 Lantern (LAC) trigger point
1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time
7 = from group command
8 = ILA
OPTIONS NOTSET
1157 LAC Triggering Distance 1 4 Lantern (LAC) triggering distance in floors
OPTIONS NOTSET
1158 LAC Triggering Time 1 9 Lantern (LAC) advance activation time in seconds
OPTIONS NOTSET
1160 HAN Type 0 4 Audible floor passing signal in car
0 = disabled
1 = HAN C, continuous operation
2 = HAN B, activated by button in COP, activated until moving direction changes
3 = HAN T, activated by button, toggle operation, first press ON second press OFF
4 = HAN S, activated by switch
OPTIONS NOTSET
1161 Overload Polarity 0 1 Overload polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
OPTIONS NOTSET
1162 Full Load Polarity 0 1 Full load polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
OPTIONS NOTSET
1168 CPI Triggering Point 0 1 Car position display (CPI) triggering point
0 = advance floor
1 = actual floor
OPTIONS NOTSET
1169 Landing Call Registered Buzzer (CRB L) 0 1 Landing Call registered buzzer (CRB L)
0 = buzzer disabled
1 = buzzer enabled
CALLS NOTSET
1170 ACU Floor Announcements 0 250 ACU floor announcements
0 = disabled
1 ... 250 = enabled
OPTIONS BUILDING
1171 ACU Device Type 0 4 ACU device type
0 = not in use
1 = connected to OPT board
2 = model up to 32 floors
3 = model up to 64 floors
4 = model up to 127 floors (KCEACU)
OPTIONS BUILDING
1172 ACU DCS Feature 0 1 ACU operation in car with DCS
0 = enabled for handicapped calls only
1 = enabled always
OPTIONS BUILDING
1173 ACU Overloaded Announcement 0 1 ACU 'overloaded' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1174 ACU Going Up Announcement 0 1 ACU 'going up' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1175 ACU Going Down Announcement 0 1 ACU 'going down' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1176 ACU Obstruction From Doors Announcement 0 1 ACU 'obstruction from doors' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1177 ACU Required For Emergency Announcement 0 1 Enable/Disable ACU
'Elevator required for an emergency. Please leave lift when door opens' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1178 ACU Earthquake Announcement 0 1 ACU 'earthquake' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1179 ACU Power Failure Announcement 0 1 ACU 'power failure' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1180 ACU Fire Alarm Announcement 0 1 ACU 'fire alarm' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1181 ACU Doors Closing Announcement 0 1 ACU 'door closing' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1182 ACU Doors Opening Announcement 0 1 ACU 'door opening' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1183 ACU Please Leave Lift Announcement 0 1 ACU 'please leave lift' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1184 ACU Transfer Floor Announcement 0 1 ACU 'transfer floor' announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1185 ACU language 0 50 Language selection for ACU
0=None, 1=Arabic, 2=Chinese, 3=Czech, 4=Danish, 5=Dutch, 6=UK English, 7=Estonian, 8=Finnish, 9=Flemish, 10=French, 11=German, 12=Greek, 13=Hungarian, 14=Italian, 15=Japanese, 16=Korean, 17=Latin, 18=Latvian, 19=Lithuanian, 20=Norwegian, 21=Polish, 22=Portugal, 23=Portuguese, 24=Russian, 25=Slovak, 26=Spanish, 27=Swedish, 28=Turkish, 29=Catalan, 30=Icelandic, 31=Slovenian, 32=Austrian German, 33=Mainland Chinese, 34=NA English, 35=NA French, 36=Univ English, 37=Marine English, 38=Hebrew, 39=Hebrew with AES, 40=Singapore English 1, 41=Singapore English 2, 42=Australian English 1, 43=Australian English 2, 44=English for Mandarin, 45 =Serbian, 46=Ukrainian, 47 = Croatian, 48 = Welsh, 49 = Welsh English, 50 = Irish,
Index1 = First language
Index2 = Second language
...
OPTIONS BUILDING
1186 Display Fields in Car 0 8 Display Fields in Car Display
0 = None
1 = OSI indication
2 = FRD indication
3 = OLF indication
4 = PRC indication
5 = LOC indication
6 = ATS indication
7 = HEL indication
8 = EAQ indication
OPTIONS NOTSET
1187 Display Fields at Landing 0 8 Display Fields on Landing Display
0 = None
1 = OSI indication
2 = PRC indication
3 = FRD indication
4 = HEL indication
5 = ATS indication
6 = BLF indication
7 = LOL indication
8 = EAQ indication
OPTIONS NOTSET
1188 LCD Language Primary 0 39 Primary language selection for LCD displays
0=None, 1=Arabic, 2=Chinese, 3=Czech, 4=Danish, 5=Dutch, 6=UK English, 7=Estonian, 8=Finnish, 9=Flemish, 10=French, 11=German, 12=Greek, 13=Hungarian, 14=Italian, 15=Japanese, 16=Korean, 17=Latin, 18=Latvian, 19=Lithuanian, 20=Norwegian, 21=Polish, 22=Portugal, 23=Portuguese, 24=Russian, 25=Slovak, 26=Spanish, 27=Swedish, 28=Turkish, 29=Catalan, 30=Icelandic, 31=Slovenian, 32=Austrian German, 33=Mainland Chinese, 34=NA English, 35=NA French, 36=Univ English, 37=Marine English, 38=Hebrew, 39=Hebrew with AES
OPTIONS BUILDING
1189 LCD Language Secondary 0 39 Secondary language selection for LCD displays
0=None, 1=Arabic, 2=Chinese, 3=Czech, 4=Danish, 5=Dutch, 6=UK English, 7=Estonian, 8=Finnish, 9=Flemish, 10=French, 11=German, 12=Greek, 13=Hungarian, 14=Italian, 15=Japanese, 16=Korean, 17=Latin, 18=Latvian, 19=Lithuanian, 20=Norwegian, 21=Polish, 22=Portugal, 23=Portuguese, 24=Russian, 25=Slovak, 26=Spanish, 27=Swedish, 28=Turkish, 29=Catalan, 30=Icelandic, 31=Slovenian, 32=Austrian German, 33=Mainland Chinese, 34=NA English, 35=NA French, 36=Univ English, 37=Marine English, 38=Hebrew, 39=Hebrew with AES
OPTIONS BUILDING
1190 Parking Type (PAD) 0 2 Enable/Disable PAD
0 = PAD disabled
1 = PAD C/O enabled
2 = PAD S enabled
PARKING NOTSET
1191 Parking Floor (PAD) 0 250 PAD floor
0 = parking to main floor
1 ... 250 = parking floor
PARKING NOTSET
1192 Parking Door (PAD) 0 7 Door operation at parking floor
0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C doors open
PARKING DOOR
1193 Parking Delay (PAD) 5 300 Timeout for parking in seconds
PARKING TIMES
1194 Basic SPI in Car 0 1 SPI message type for car displays
0 = extended SPI
1 = basic SPI (old old graphical displays e.g. DELEL and EP1)
OPTIONS NOTSET
1195 Basic SPI at landing 0 1 SPI message type for landing displays
0 = extended SPI
1 = basic SPI (old old graphical displays e.g. DELEL and EP1)
OPTIONS NOTSET
1196 FCC C feature 0 1 False Car Call Cancel by Counting Stops, FCC C
0 = disabled
1 = enabled
CALLS NOTSET
1197 FCC Number of Allowed Stops 1 10 Number of consecutive stops without photocell cuts to cancel car calls
CALLS NOTSET
1198 FCC R feature 0 2 False Car Call Cancel by Re-pushing Car Call Button, FCC R
0 = disabled
1 = enabled, car call cancellation, one push
2 = enabled, car call cancellation, two push
CALLS NOTSET
1199 FCC L feature 0 1 False Car Call Cancel by Measuring Load, FCC L
0 = disabled
1 = enabled
CALLS NOTSET
1200 Drive Interface Type 1 3 Drive interface type
1 = serial interface (KDSI2)
2 = parallel interface (Yaskawa 7-speed)
3 = parallel interface (Hydro)
DRIVE NOTSET
1201 Correction drive ( COD) feature 0 1 Correction drive (COD)
0 = disabled
1 = enabled

DRIVE NOTSET
1202 Accurate Relevelling ACL Type 0 3 Accurate relevelling (ACL) type
0 = disabled
1 = ACL doors closed enabled, door opening after ACL
2 = ACL doors closed enabled, door opening before ACL
3 = ACL doors open enabled
DRIVE NOTSET
1203 Start Supervision Timeout 1 120 Start supervision timeout in 0,1 s steps.
DRIVE TIMES
1204 Maximum Number for Failed Starts 1 10 Maximum number for failed starts
DRIVE LIMITS
1205 Stop Delay 0 100 Stop delay in 0,1 s steps between two consecutive starts.
DRIVE TIMES
1206 Stop Delay for Relevelling 0 100 Stop delay for relevelling in 0,1 s steps
DRIVE TIMES
1207 Final Stopping Point 0 126 Final stopping point
Distance in 1 mm steps from accurate floor level, normal run
DRIVE LIMITS
1209 V3F Stop Delay Normal Drive 10 200 Time interval in 10 ms steps from speed level signal to stop signal at stopping phase.
DRIVE TIMES
1210 V3F Stop Delay At Inspection Drive 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping phase.
DRIVE TIMES
1211 V3F Stop Delay for Releveling 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping phase.
DRIVE TIMES
1212 V3F Stop Delay for EBD Drive 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping phase.
DRIVE TIMES
1213 V3F Fault Signal Polarity 0 1 Polarity of V3F fault signal
0 = LOW, NO contact
1 = HIGH, NC contact
DRIVE NOTSET
1214 Maximum Number of Failed Relevelling (ACL) Attempts 1 15 Maximum number of failed ACL attempts
DRIVE LIMITS
1215 Maximum Number of Releveling Attempts (ACL) 1 30 Maximum number of ACL runs at level.
DRIVE LIMITS
1216 Maximum Drive Time for Releveling (ACL) 10 200 Maximum drive time in 0,1 s steps for releveling.
DRIVE TIMES
1217 Final Releveling Stopping Point (ACL) 0 126 Defines distance in 1 mm steps  from accurate floor level.
DRIVE LIMITS
1220 Short Floor Distance (SFD) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1221 Short Floor Length 200 3000 Maximum length for short floor in millimeters
OPTIONS NOTSET
1222 TTC Floor Offset 30 60 Defines the maximum side to side offset in millimeters for TTC floor.
DRIVE LIMITS
1230 Hydro Valve Type 1 8 Valve type for Hydraulic elevator
1 = Hydronic 300
2 = Hydronic 300S
3 = FIAM
4 = GMV
5 = Beringer
6 = iValve
7 = Hydronic 200
8 = Beringer High Speed
DRIVE NOTSET
1231 Star Time for Hydro 0 20 Star time in 0,1 s steps for DOL or Star/Delta pump start sequence with a hydraulic elevator.
0 = Direct (DOL) start
1 ... 20 = Star ON time before Delta
DRIVE TIMES
1232 Pump Off Delay for Hydro 0 50 Delay in 0,1 s steps to keep pump on after up valve is switched off
DRIVE TIMES
1233 Service Speed Level for Hydro 1 2 1 = Low speed
2 = High speed
DRIVE NOTSET
1234 Delay After Delta 1 50 Delay in 0,1 s steps between delta on and control signals.
DRIVE TIMES
1235 Final Stopping Point Up for Hydro 0 126 Final stopping point for up direction, hydraulic elevator
Distance in 1 mm steps from accurate floor level
DRIVE LIMITS
1236 Final Stopping Point Down for Hydro 0 126 Final stopping point for down direction, hydraulic elevator
Distance in 1 mm steps from accurate floor level
DRIVE LIMITS
1237 Pilot Valve Delay 1 30 Delay in 0,1 s steps for Hydronic 200 pilot valve.
Used only if direct (DOL) start in use.
DRIVE TIMES
1238 Anti Creep Device Feature (ACD) 0 1 0 = disabled
1 = enabled
DRIVE NOTSET
1239 Anti Creep Zone Upper Limit 0 50 Upper limit for anti creep device releasing.
Distance in 1 mm steps from accurate floor level.
DRIVE LIMITS
1240 Anticreep Device Contact Polarity 0 1 Polarity of anti creep device contact.
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
DRIVE NOTSET
1298 Deceleration Point Offset 0 75 The point on which the elevator starts to decelerate on deceleration magnet.
Offset in 1 mm steps from the middle of the magnet.
DRIVE LIMITS
1299 Relevelling (ACL) Distance 2 40 Distance in 1 mm steps from door zone's zero middle point
DRIVE LIMITS
1302 EMO Indication in Car 0 1 EMO indication in car
0 = light
1 = light and buzzer
OPTIONS NOTSET
1303 MRT Return Floor 0 250 Machine room temperature (MRT) return floor
0 = stops to destination floor, stays at current floor
1 ... 250  = specified return floor
OPTIONS NOTSET
1304 CSM Type 0 6 Compulsory stopping at main floor (CSM)
0 = Disabled
1 = Both directions, normal door operation, CSM BN
2 = Down direction, normal door operation, CSM DN
3 = Up direction, normal door operation, CSM UN
4 = Both direction, security door operation, CSM BS
5 = Down direction, security door operation, CSM DS
6 = Up direction, security door operation, CSM US
OPTIONS NOTSET
1305 CIC Time 0 10 Corridor Illumination Control (CIC)
0 = disabled
1 ... 10: delay in seconds to switch illumination off after elevator has stopped
OPTIONS TIMES
1306 LIL Type 0 3 Elevator link (LIL) feature
0 = LIL AB/C, alarm devices + binary coded and analog car position
1 = LIL AMB/C, alarm devices + mode signals + binary coded and analog car position
2 = LIL ASB/C, alarm devices + status signals + binary coded and analog car position
3 = LIL AMB/C + ASB/C (all) signals enabled
OPTIONS NOTSET
1307 MRT Type 0 1 Machine room temperature supervision (MRT)
0 = disabled
1 = enabled
OPTIONS NOTSET
1308 EAQ Type 0 2 Earthquake  (EAQ) feature
0 = disableb
1 = enabled
2 = EN 81-77:2013
OPTIONS NOTSET
1309 EAQ Memory 0 1 Memory for EAQ counterweight derailment and seismic detection
0 = disabled
1 = enabled (reset required)
OPTIONS NOTSET
1310 EAQ Seismic Operation 0 1 Operation for  EAQ seismic detection
0 = Elevator stops to nearest possible floor with reduced speed
1 = Elevator emergency stops and makes a correction drive to nearest possible floor
OPTIONS NOTSET
1311 PFD in Use 0 2 Phase Failure Detection supervision with KCEPFD board
0 = disabled
1 = Phase Failure Detection (PDD N) enabled
2 = Phase Failure and Reversal Detection (PDD R) enabled
OPTIONS NOTSET
1312 EBD Type 0 2 Emergency battery drive  (EBD)
0 = disabled
1 = SELCOM device
2 = SSB or ERD device
OPTIONS EMERGENCY 
1313 FRE Floor 0 250 Return floor level for fast recall service (FRE)
0 = disabled
1 ... 250 = return floor number
OPTIONS NOTSET
1314 FRE Door Side 0 7 Door opening side at fast recall service (FRE) return floor
0 = disabled
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open
OPTIONS NOTSET
1315 Water Sensor Contact Type (WSC) 0 4 Water Sensor Contact (WSC) feature
0 = disabled
1 = homing operation (WSC O)
2 = to nearest floor operation (WSC N)
3 = marine operation (WSC MA)
4 = continuous operation (WSC C)
OPTIONS NOTSET
1316 Water Sensor Contact Return Floor (WSC) 0 250 Water sensor contact (WSC) return floor
0 = nearest floor
1 ... 250 = specified return floor
OPTIONS NOTSET
1317 Water Sensor Contact Indication (WSC) 0 2 Additional indications for WSC mode
0 = disabled
1 = returned indication
2 = returned indication with returning buzzer
OPTIONS NOTSET
1318 Standby Mode for Displays 0 1 Standby mode for displays
0 = disabled
1 = enabled
OPTIONS NOTSET
1319 ECO Mode Timeout 600 12000 Timeout in 0,1 s steps for stand by mode after last run.
OPTIONS TIMES
1320 Fire Protection Door Type (FPD) 0 3 Fire protection door (FPD) feature
0 = disabled
1 = FPD *O enabled
2 = FPD *T enabled
3 = FPD HK enabled
OPTIONS FRD
1322 Standing Doors Open  Feature (SDO) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1323 SDO Type 0 1 Standing Doors Open (SDO) type
0 = all floors
1 = main floor
OPTIONS NOTSET
1326 Lift Not in Bank Timeout 10 240 Delay in seconds to set lift not in bank state if lift is not able to serve landing calls on that moment for some reason.
OPTIONS TIMES
1327 Pit Inspection Supervision 0 1 0 = disabled
1 = enabled

OPTIONS NOTSET
1329 Standby Mode Request to MSC Board 0 1 Standby mode request to MSC board
0 = disabled
1 = enabled
OPTIONS NOTSET
1330 Elevator Identifier Feature (EID) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1331 Elevator Identifier Operation after Lift Is Nominated (EID) 0 2 Elevator Identifier (EID) operation after lift is selected
0 = disabled (EID E/F)
1 = light constantly on (EID C/G)
2 = light flashing (EID D)
OPTIONS NOTSET
1332 Elevator Identifier Operation During Deceleration (EID) 0 2 Elevator Identifier (EID) operation while decelerating to serve call
0 = disabled
1 = constantly on (EID C/D/E)
2 = flashing (EID B/F/G)
OPTIONS NOTSET
1333 Elevator Identifier Architrave Operation after Lift Is Nominated (EID) 0 2 Elevator Identifier (EID) architrave illumination after call has been allocated
0 = disabled (EID E/F)
1 = constantly on (EID C/G)
2 = flashing (EID D)
OPTIONS NOTSET
1334 Elevator Identifier Architrave Operation During Deceleration (EID) 0 2 Elevator Identifier (EID) architrave illumination after starting to decelerate
0 = disabled
1 = constantly on (EID C/D/E)
2 = flashing (EID B/F/G)
OPTIONS NOTSET
1335 Elevator Identifier Audible Guidance for Handicapped Enabled (EID HAN D) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1336 EID HAN D audible guidance duration 0 3600 Minimum duration for HAN D audible guidance in seconds. It his time value is longer than walking time value of a handicap call, it will override walking time as the duration of audio guidance. Guidance sound always stops when door starts closing at source floor no matter of walking time or this parameter, so the default value of 5 minutes essentially means that the audio guidance will be heard from allocation to door close. If call is not served during this duration, this is also the maximum duration of audio guidance.
OPTIONS NOTSET
1340 Destination Indicator in Car (DIN C) 0 1 Destination indicator in car (DIN C) showing given calls from floor for entering passengers.
0 = disabled
1 = enabled
OPTIONS NOTSET
1341 Destination Indicator in Car (DIN N) 0 1 Destination indicator in car (DIN N) showing next stops for passengers.
0 = disabled
1 = enabled
OPTIONS NOTSET
1342 Destination Indicator at Landing (DIN L) 0 1 Destination indicator at landing showing to passengers the destination floors.
0 = disabled
1 = enabled
OPTIONS NOTSET
1343 Stopping Accuracy Monitoring 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1344 Stopping Inaccurate Limit 1 7 Number of allowed inaccurate stops for monitoring.
OPTIONS NOTSET
1345 Stopping Accuracy Monitoring Count 1 32 Number of consecutive accurate stops.
OPTIONS NOTSET
1346 Stopping Accuracy Monitoring Distance 5 50 Stopping accuracy monitoring distance for a stop in 1 mm steps.
OPTIONS NOTSET
1347 Stopping Accuracy Monitoring Time 1 100 Accuracy stopping monitoring time in 10 ms steps after main contactor de-energizing.
OPTIONS TIMES
1348 Out of Door Zone Monitoring 0 1 Out of Door Zone monitoring
0 = disabled
1 = enabled
OPTIONS NOTSET
1349 Out of Door Zone Monitoring Time 1 300 Defines time in seconds to trigger fault code for elevator stopped between floor levels.
OPTIONS TIMES
1350 Automatic Return to Lowest Floor (ARH) Time 0 120 Defines time for automatic return to lowest floor for Hydraulic elevator (ARH)
0 = disabled
1 or more = time for automatic return in minutes
OPTIONS NOTSET
1351 FCC R Time 0 50 Timeout in 0,1 s for car call cancelling with second push FCC R.
OPTIONS TIMES
1352 Door Close Command Keep Active Time 1 10 Timeout in seconds to keep door close command activated for SSA or PIT INSPECTION reset.
OPTIONS TIMES
1353 Door Contacts Bypassed Indication Type 0 3 Door contact bypassing indication type
0 = Constant light, buzzer turned on when contact is bypassed  and lift is moving
1 = Flashing light, buzzer turned on when contact is bypassed  and lift is moving
2 = Constant light, buzzer turned on when contact is bypassed
3 = Flashing light, buzzer turned on when contact is bypassed
OPTIONS NOTSET
1354 Penthouse Visitor Feature (PVS) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1355 Empty Car Detection Type 0 2 0 = nominal load parameter
1 = sensor
2 = both nominal load and  sensor
OPTIONS NOTSET
1356 Car Call Unlocking Timer for PVS 5 120 Timeout in seconds for keeping car call unlocked during Penthouse Visitor mode
OPTIONS TIMES
1357 Empty Car Load Limit 0 50 Defines limit in percentages for empty car load detection.
OPTIONS NOTSET
1358 By Pass Indication (BPI) Feature 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1359 By Pass Indication (BPI) Type 0 1 Bypass indication at landing type
0 = indication at bypassed floor
1 = indication at all floors when bypassing
OPTIONS NOTSET
1360 Landing Call Light Blinking (LCL B) 0 1 Landing call light blinking
0 = disableb
1 = enabled
OPTIONS NOTSET
1361 Landing Call Light Blinking Type 0 1 Landing call light blinking type
0 = blinking when elevator is moving
1 = blinking always
OPTIONS NOTSET
1362 Landing Call Blinking Frequence 2 20 Interval time in 0,1 s for landing call light blinking
OPTIONS TIMES
1363 EBD Shut Down Timeout 3 120 Specific shut down timeout in seconds after EBD return. Timeout starts when door is fully opened.
OPTIONS EMERGENCY 
1364 EBD Door Operation 0 1 Door operation in EBD mode
0 = door closes after EBD/FID door open time
1 = door remains open
OPTIONS EMERGENCY 
1365 RBO device monitoring 0 1 Rescue Brake Opening (RBO) device monitoring
0 = disabled
1 = enabled
OPTIONS NOTSET
1366 RBO fault type 0 1 Rescue Brake Opening (RBO) fault type
0 = warning, elevator stays in service
1 = fatal, elevator stays out of service
OPTIONS NOTSET
1367 RBO Device Floor 0 250 Rescue Brake Opening (RBO) device floor  
0 = highest floor
1 ... 250  = RBO device floor
OPTIONS NOTSET
1368 RBO Device Side 0 3 Defines RBO device side at TTC floor
1 = A side
2 = B side
3 = C side
OPTIONS NOTSET
1369 Time for Bypass Indication 5 50 Time in 0,1 s steps for bypass indication at landing.
OPTIONS TIMES
1370 Belt Monitoring Delay 1 60 Delay in seconds to trigger belt tensioning when elevator is vacant.
OPTIONS TIMES
1371 Belt Monitoring Floor 0 248 Belt tensioning floor, 1 ... 250.
OPTIONS NOTSET
1372 Belt Monitoring Time 1 250 Time in seconds for belt tensioning.
OPTIONS TIMES
1373 Belt Tensioning Interval Time 5 1440 Defines time interval in minutes for belt tensioning.
OPTIONS TIMES
1374 Belt Monitoring 0 1 Belt Monitoring for NanoSpace elevator
0 = disabled
1 = enabled
OPTIONS NOTSET
1375 Attendant Service Feature (ATS) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1376 ATS Type 0 0 Attendant service (ATS) type
0 = ATS C
OPTIONS NOTSET
1377 ATS Buzzer 0 1 Attendant service (ATS) buzzer
0 = disabled
1 = enabled
OPTIONS NOTSET
1378 RES Speed 0 25 Defines lower speed in 0,1 m/s steps to be used during special elevator features
0 = nominal speed in use
1 ... 20 = speed in m/s
OPTIONS NOTSET
1379 Emo Fault Memory 0 1 Defines if emergency stop by swing door safety ray is memorized
0 = disabled
1 = enabled
OPTIONS NOTSET
1383 Power UP Delay Feature (PUD) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1384 Power Up Delay Time 0 900 Power Up delay time in seconds
OPTIONS TIMES
1385 Primary Wave Detector, EN 81-77 0 1 Primary wave detection, EN 81-77:2013.
0 = disableb
1 = enabled
OPTIONS NOTSET
1386 EAQ Primary Wave Timer, EN81 77 1 300 Primary wave detection timer in seconds, EN 81-77:2013.
OPTIONS TIMES
1387 EAQ Seismic Detection Test Time, EN81 77 2 1440 Seismic detection test interval time in minutes, EN 81-77:2013.
OPTIONS TIMES
1388 Hydro Oil Temperature Supervision 0 1 Hydro oil temperature supervision
0 = disableb
1 = enabled
OPTIONS NOTSET
1389 Hydro Oil Temperature Recovery Time 0 600 Timeout in seconds for automatic recovery from oil temperature fault
OPTIONS TIMES
1390 EPD Type 0 2 Emergency power drive (EPD)
0 = disabled
1 = enabled, external sequencer
2 = enabled, internal sequencer
OPTIONS EMERGENCY 
1391 EPD Return Floor 0 250 Return floor for Emergency Power Drive (EPD).
0 = return drive to nearest floor
1...250 = return floor number
OPTIONS EMERGENCY 
1392 EPD Door Open Side 0 7 Door opening side at Emergency Power Drive (EPD) return floor
0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open
OPTIONS EMERGENCY 
1393 EPD Car Light and Fan Operation 0 1 Car light and car fan operation after EPD return drive.
0 = OFF immediately
1 = OFF after timeout defined by parameter
OPTIONS EMERGENCY 
1394 Car Light Control during Service Modes 0 2 Car light control during service drive modes
0 = car light permanently OFF
1 = car light permanently ON
2 = car light OFF after car light delay when elevator is stopped
OPTIONS CAR
1395 Car Ventilation Control during Service Modes 0 2 Car ventilation control during service drive modes
0 = car ventilation permanently OFF
1 = car lventilation permanently ON
2 = car ventilation OFF after car ventilation delay when elevator is stopped
OPTIONS CAR
1396 Emergency Power (EPD) Speed 0 20 Defines driving speed in 0,1 m/s steps used under emergency power (EPD)
0 = nominal speed in use
1 ... 20 = speed in m/s
OPTIONS EMERGENCY 
1397 Well Access Protection Feature (WAP) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1398 Well Access Protection Timeout 10 120 Timeout for well access protection mode in seconds
OPTIONS TIMES
1399 Car Height 2000 4000 Car height in millimeters.
OPTIONS NOTSET
1401 FID Building in Use 0 2 Fire Detection for whole building (FID B & FID A)
0 = FIB B* and FID A* disabled
1 = FID B* enabled
2 = FIB B* and FID A* enabled
OPTIONS FRD
1402 FID Machine Room in Use 0 2 Fire Detection in machine room (FID M)
0 = disabled
1 = enabled, return to nearest floor
2 = enabled, return to main floor
OPTIONS FRD
1403 FID Shaft in Use 0 1 Fire Detection at landing (FID S)
0 = disabled
1 = enabled
OPTIONS FRD
1405 FID Return Floor Main 0 250 Main return floor level for Fire Detection (FID).
0 = return drive to nearest floor
1 ... 250 = return floor number
OPTIONS FRD
1406 FID Return Floor Alternative 0 250 Alternative return floor level for Fire Detection (FID).
0 = return drive to nearest floor
1 ... 250 = return floor number
OPTIONS FRD
1408 FID Door Open Side Main 0 10 Door opening side at main fire detection return floor (FID B/S)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed
OPTIONS FRD
1409 FID Door Open Side Alternative 0 10 Door opening side at alternative fire detection return floor (FID A)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed
OPTIONS FRD
1410 FID_M Door Opening Side 0 10 Door opening side at floor for machine room fire detection (FID M)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed
OPTIONS FRD
1411 FID DOB Operation 0 1 Door open button (DOB) operation during fire detection (FID) or during FRD priority recall (phase 1)
0 = DOB remains inoperative
1 = DOB remains operative
OPTIONS FRD
1413 FID Door Opening by Car Call at Return Floor 0 1 Door opening by car call at fire evacuation floor
0 = disabled
1 = enabled
OPTIONS FRD
1414 FID Door Opening by Landing Call at Return Floor 0 1 Door opening by landing call at fire evacuation floor
0 = disabled
1 = enabled
OPTIONS FRD
1415 FID Car Light and Fan Operation 0 1 Car light and car fan operation after fire detection return drive.
0 = OFF immediately
1 = OFF after timeout defined by parameter
OPTIONS FRD
1416 FID Machine Room Detector Priority 0 1 Defines the priority for machine room fire detection against fireman's drive mode
0 = FRD overrides FID M
1 = FID M overrides FRD
OPTIONS FRD
1417 FID Memory 0 1 0 = disabled
1 = enabled (separate FID reset input needed)
OPTIONS FRD
1418 FID Door Open Time 10 600 Specific door open time for fire detection for fireman's drive (phase 1) in 0.1 s steps.
OPTIONS FRD
1419 FCB FID Input Location 0 8 FID Input on FCB board
0 = FID input not in use
1 = FID Input, A side
2 = FID Input, B side
3 = FID Input, A & B side
4 = FID Input, C side
5 = FID Input, A & C side
6 = FID Input, B & C side
7 = FID Input, A & B & C side
OPTIONS FRD
1420 FRD in Use 0 3 Fireman's drive mode (FRD)
0 = disabled
1 = enabled, returning and service phases
2 = enabled, service phase only
3 = enabled, returning phase only
OPTIONS FRD
1421 FRD Return Floor 1 250 Fire service access floor level for firefighters to gain access to the fireman's lift.
1 ... 250 = Fireman's return floor number
OPTIONS FRD
1422 FRD Return Floor Side 1 7 Door opening side at fire service access level for firefighters to gain access to the fireman's lift.
1 = A side
2 = B side
3 = A & B side
4 = C side
5 = A & C side
6 = B & C side
7 = A & B & C side
OPTIONS FRD
1423 FRD Return Floor Door Operation 0 1 Door operation at fire service access level for firefighters to gain access to the fireman's lift.
0 = hold open
1 = closed after predefined time
OPTIONS FRD
1424 FRD Serving Phase Door Closing 0 5 Defines how door is closed during FRD serving phase
0 = Car Call Momentary
1 = DCB Momentary
2 = Car Call or DCB Momentary
3 = Car Call Continuous
4 = DCB Continuous
5 = Car Call or DCB Continuous
OPTIONS FRD
1425 FRD Serving Phase Door Opening 0 3 Defines how door is opened during FRD serving phase
0 = Auto Opening
1 = DOB Momentary
2 = DOB Continuous Reclose
3 = DOB Continuous Stop
OPTIONS FRD
1426 FRD Serving Phase Car Call Registering 0 1 Defines how car call is registered during FRD serving phase
0 = multiple car calls can be registered simultaneously
1 = only one car call can be registered at a time

OPTIONS FRD
1427 FRD Serving Phase Activation 0 3 Fireman's drive serving phase activation
0 = enabled by FRD switch in car after fireman's returning phase only
1 = enabled by FRD switch in car without fireman's returning phase
2 = enabled by FRD landing switch
3 = enabled by FRD landing switch at main and alternative
OPTIONS FRD
1428 FRD Serving Phase Activation Timeout 0 25 Defines timeout in seconds to switch lift to fireman's serving phase after returning phase has been completed
OPTIONS FRD
1429 FRD Serving Phase Deactivation 0 5 Fireman's drive serving phase deactivation
0 = switch in car turned off at return floor
1 = switch in car and at landing turned off at return floor
2 = switch in car turned off at any floor
3 = switch in car and at landing turned off at any floor
4 = switch in car turned off and switch at landing turned off or lift at return floor
5 = switch in car turned off and lift at any floor or landing switch is on
OPTIONS FRD
1430 FRD Serving Phase Deactivation Door Status 0 2 Door state to complete fireman's drive serving phase at fireman's return floor.
0 = with any door state
1 = door is fully opened at return side
2 = door is fully opened at any side
OPTIONS FRD
1431 FRD Serving Phase Deactivation Door Non Return 0 3 Door state to complete fireman's drive serving phase at non fireman's return flloor
0 = with any door state
1 = door is fully opened at return side
2 = door is fully opened at any side
3 = all doors closed
OPTIONS FRD
1432 FRD Serving Phase Deactivation Timeout 0 30 Timeout in seconds to switch lift off from fireman's serving phase
OPTIONS FRD
1433 FRD Auto Opening At Return Floor 0 1 Automatic door opening at fireman's return floor during fireman's serving phase
0 = disabled
1 = enabled
OPTIONS FRD
1434 FRD DOB Light Illumination 0 2 FRD DOB light operation
0 = disabled
1 = flashing
2 = constant
OPTIONS FRD
1435 FRD Return Floor Alternative 1 250 Fire service alternative access floor level for firefighters to gain access to the fireman's lift.
1 ... 250 = Fireman's return floor number
OPTIONS FRD
1436 FRD Return Floor Side Alternative 1 7 Door opening side at fire service alternative access level for firefighters to gain access to the fireman's lift.
1 = A side
2 = B side
3 = A & B side
4 = C side
5 = A & C side
6 = B & C side
7 = A & B & C side
OPTIONS FRD
1437 FRD Return Floor Door Operation Alternative 0 1 Door operation at fire service alternative access level for firefighters to gain access to the fireman's lift.
0 = hold open
1 = closed after predefined time
OPTIONS FRD
1440 Allowed FRD Floors 0 7 Allowed floor sides during Fireman's serving phase.
0 = not in use
1 = A side in use
2 = B side in use
3 = A & B sides in use
4 = C side in use
5 = A & C sides in use
6 = B & C sides in use
7 = A & B & C sides in use
OPTIONS FRD
1441 FRD FID Indication 0 1 Mode indication shown in car and at landing during fire detection (fireman's drive phase 1)
0 = Fireman’s drive (FRD)
1 = Fire detection (FID)
OPTIONS FRD
1442 FRD Country 0 22 Country code for Fireman's drive mode
0 = None
1 = BE, Belgium
2 = CS, Pubel Code
3 = DE, Germany
4 = EN 81:2003_O
5 = EN 81:2003_T
6 = FR, France
7 = NL, Netherlands
8 = RU, Russia (GOST 52382:2010)
9 = SE, Sweden
10 = N_UK, United Kingdom
11 = S_UK, United Kingdom
12 = AE, United Arab Emirates
13 = HK, Hong Kong
14 = CN, China
15 = EN 81:2015_O
16 = EN 81:2015_T
17 = MY, Malesia
18 = SG, Singapore
19 = AU, Australia
20 = AU1 Ausralia
21 = NZ, New Zealand
22 = IL, Israel
OPTIONS FRD
1443 FID Door Closing Speed 0 1 Defines door closing speed when FID detected
0 = normal speed
1 = nudging speed
OPTIONS FRD
1444 FRD Override Mode Timeout 0 180 Timeout in seconds for overriding existing mode by FRD.
0 = no automatic override when door open
1 ... max = Force door closing by FRD after this timeout

Index1 (ATS)
Index2 (PRC)
OPTIONS FRD
1445 FRD Car Call Cancel by Door Reopen 0 1 Defines car call cancel when door is reopens during FRD phase 2
0 = disabled
1 = enabled
OPTIONS FRD
1446 FRD Car Call Registering during Deceleration 0 1 Defines car call registering while decelerating
0 = disabled
1 = enabled
OPTIONS FRD
1447 FRD_EVA_Elevator_Type 0 2 Defines whether elevator shall be used as fire lift, EVA lift or secondary EVA lift.
0 = fire lift
1 = EVA lift
2 = Secondary EVA lift
OPTIONS FRD
1448 Shandong Indication 0 1 Defines Shandong indication (FDI) during firemans drive
0 = disabled
1 = enabled
OPTIONS FRD
1450 Automatic Elevator Service Feature (AES) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1451 AES Stop Floors 0 3 0 = not allowed
1 = down
2 = up
3 = down & up
OPTIONS NOTSET
1452 AES Door Time at Main Floor 10 240 AES door open time in seconds at main floor
OPTIONS TIMES
1453 AES Door Time at Other Floors 10 240 AES door open time in seconds at other floors
OPTIONS TIMES
1454 AES Calls 0 3 0 = car and landing calls disabled
1 = car calls enabled and landing calls disabled
2 = car calls disabled and landing calls enabled
3 = car and landing calls enabled
OPTIONS NOTSET
1455 AES Floor 0 3 0 = Main floor
1 = Floor where lift stops after serving existing calls
2 = Main floor with AES stop floors served
3 = Floor where lift stops after serving existing calls with AES stop floors served
OPTIONS NOTSET
1456 AES Car Call Lights 0 2 0 = Normal car call button lights
1 = Illuminate all car call button lights
2 = Illuminate car call button lights as per AES stop floors
OPTIONS NOTSET
1457 AES Display 0 3 0 = No AES display
1 = AES display in car
2 = AES display at landing
3 = AES display in car and at landing
OPTIONS NOTSET
1458 AES Buzzer 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1459 AES Relevelling Permission 0 1 0 = ACL Disabled
1 = ACL B doors open enabled
OPTIONS NOTSET
1460 AES Clock Switch 0 3 0 = not in use
1 = in use and elevator will be in normal mode
2 = in use and elevator goes to standby mode with doors closed
3 = in use and elevator goes to standby mode with doors open
OPTIONS NOTSET
1461 AES Landing Indication Type 0 1 0 = Out of Service Indication
1 = AES indication
OPTIONS NOTSET
1462 Reduced Speed Feature (RES) 0 2 0 = disabled
1 = enabled, external timer (RES E)
2 = enabled, internal timer (RES I)
OPTIONS NOTSET
1463 Silent Night Feature (SNF) 0 2 0 = disabled
1 = enabled, external timer (SNF E)
2 = enabled, internal timer (SNF I)
OPTIONS NOTSET
1464 Lock Single Lift Operation Car Calls 0 1 Car call lock from group/E-link operation when group disconnects.
0 = Last received car call lock status
1 = All open, All car call locks are set unlocked
LOCKS NOTSET
1465 ACU volume 0 10 Announcement (ACU) volume adjustment
0 = OFF
1 ... 10 = volume level
OPTIONS BUILDING
1469 Door Open Monitoring Feature (DOM) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1470 Priority Call in Car Feature 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1471 Out of Service Feature (OSS) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1479 KCEMSC Periodical Test Time In Hours 0 23 KCEMSC Periodical Test Window Open In Hours
OPTIONS  TIMES
1480 Automatic Dispatching from Floor Feature (ADF) 0 1 0 = disabled
1 = enabled
OPTIONS NOTSET
1481 ADF Dispatch Floor 1 250 Automatic Dispatch Floor (ADF)
1 ... 250 = floor number for automatic dispatch
OPTIONS NOTSET
1482 ADF Destination Floor 0 250 Automatic Destination Floor (ADF)
0 == main floor
1 ... 250 = destination floor for elevator dispacthing
OPTIONS NOTSET
1483 Lantern Control at Terminal Floors 0 3 Lantern control at terminal floor
0 = similar to intermediate floor (default)
1 = both arrows controlled up at lowest floor
2 = both arrows controlled down at highest floor
3 = both arrows controlled up at lowest floor and down at highest floor
OPTIONS NOTSET
1484 ACU Required for Evacuation Announcement 0 1 Elevator Required for Evacuation. Please Leave Lift When Door Opens Announcement
0 = disabled
1 = enabled
OPTIONS BUILDING
1485 KCEPIO Rate Limit 1 50 Filtering time to send input state updates from node in 10 ms steps.
OPTIONS TIMES
1490 Battery Stress Test Interval Time 72 8760 Car roof emergency battery stress test interval time in hours (h).
OPTIONS TIMES
1491 Battery Stress Test Fault Type 0 1 Car roof emergency battery stress test fault type
0 = warning, elevator stays in service
1 = fatal, elevator stays out of service
OPTIONS NOTSET
1492 Battery Stress Test Duration 1 600 Defines duration time in minutes for emergency battery stress test.
OPTIONS TIMES
1493 Battery Stress Test Fault Level 105 125 Defines voltage level for emergency battery stress test.
Value is voltage x 10.
OPTIONS NOTSET